Release 1.0.5.97 (2024-10-07): Release 1.0.5.97 (2024-10-04): Release 1.0.5.96 (2024-10-04): - Fixed an error in the unit conversion window. - Added DLMS card. - Added new properties for NB IoT modem. - Option to export modbus map to XLS format. - Added the option of scrolling in the window of actual values. - Expansion of the quick button map. Release 1.0.5.95 (2024-08-27): - Added DLMS card that can be edited in the PRO version. - Extended modem status for newer modems. - The status in the archive line can now be closed via the button. - The AMR window can be placed in the toolbar and then continue working in the program. Release 1.0.5.94 (2024-08-19): - Extends map elements. - Fix display of battery image. - Modification of device call processing. - The modem error is now displayed as text and not as a number. In the modem status window. Release 1.0.5.93 (2024-08-01): - Correction of display of module parameters on the device. - Correction of the display of the PWR4 module. - Correction of display of some columns in maps. Release 1.0.5.92 (2024-07-22): - Fixes and optimizations in the actual values ??window. The chart legend can now be hidden. - Correction of register settings in the EXT1 module after writing parameters. - Changes in the Simple version. - Quick buttons map - new options Release 1.0.5.91 (2024-06-12): - Fix for encoder initialization (if not PRO version) - The actual values ??window can draw more than one measurand on the graph. - Added new language (Serbian) - Added help for abs. pressure (conversion factor) - Fixed dial number visibility (modem) Release 1.0.5.90 (2024-06-03): Release 1.0.5.89 (2024-04-24): - Fix visibility of button for module parameters. - Display modbus template ID. - Actual values chart for multiple values. - Removal of minor defects. - Adding element to modbus map, new comboBox. Release 1.0.5.88 (2024-04-12): - Code optimization. - User interface bug fixes. - Removal of minor defects. - Adding element to modbus map, new comboBox. Release 1.0.5.87 (2024-03-18): - Optimization. - Removal of minor defects. - Module check update for the device. - Address setting correction for Modbus. Release 1.0.5.86 (2024-02-16): - Correction of adding quantities in the Standard version. - Duplicate address check in parameters. - IP address format check. - Checking whether the quantity is archived in the modbus map. - Time setting optimization - Simplifying the modem card. Release 1.0.5.85 (2024-01-03): - Modification of DSFG client - Modification for modbus device - Editing in the graph window Release 1.0.5.84 (2023-12-06): - Calibration fix + pdf report - New photos in the graphics window of the modules - Modbus map new variant of ITC France - Fixes in the graphs window Release 1.0.5.82 (2023-10-20): Release 1.0.5.81 (2023-10-19): - Fix display of archives. - Device time added to FW activation window. - The switch window now has DLMS maps. - Fix for start of periodic reading. - Newly, in the program settings, you can set the folder where the read data should be saved. - Acceleration of data storage in the database. - Improved battery replacement command. Release 1.0.5.80 (2023-07-13): - Fix for breaking reading of actual values. - The program version number is displayed in the error window. - Added "New records only" option for reading archives. - The graphic window of the modules can now be opened directly from the DT_ALL file. - In the graphic window of the modules, the text of the entire configuration is displayed after hovering the mouse over the CPU module. - Fix: test/reset device status. - Fix: date display when exporting archives to XLS. Release 1.0.5.79 (2023-06-09): Release 1.0.5.78 (2023-06-07): Release 1.0.5.77 (2023-05-26): - Added help for the device display. - Optimization of archive reading. - Correction of writing the address to the sensor. - New compressibility calculation method - SGERG-mod-H2. - If the archive is exported to *.XLS, a second *.CSV file is automatically created. - The program can read new passwords/keys from a CSV file. Release 1.0.5.76 (2023-03-10): - Optimizing communication. - Fix reading modem information. - The properties of the internal counter can be edited. - Fix editing property in modbus map. Release 1.0.5.75 (2023-01-31): Release 1.0.5.74 (2023-01-20): - Archives can be read from the min time and now even up to the max time. Before, it was always read to the end. - The Modbus map can be opened directly from the menu using an XML file. - After saving the modbus map to the file, a new link is offered. - Correction of writing decimal places in the modbus map. - Binary archive view transformation. Release 1.0.5.73 (2022-12-06): - Another type of indexer is displayed in the graphical window for modules. - Improved checking of modbus map if saving with OK to PAR. - Adjustment for SRM and I/O units - New label in settings archive. Release 1.0.5.72 (2022-11-28): - Protocol name in capital letters. - Added time property for FTP client. - Display a label if there are no available COM ports. - Adaptation for Danish. Release 1.0.5.71 (2022-11-08): - Fixed switching window property. - Fix of setting on/off alarms and calls to dispatch. - Unification of some button sizes in the parameters window - Fix maximum length of the station name. Release 1.0.5.70 (2022-10-19): - Bug fix if the flow input number changes. Release 1.0.5.69 (2022-10-18): - Call/servis windows: small fixes and optimalization - Saving to PAR file: optimalization - Changes for the new FW indexer. - In the Simple version, there is a new button for exchange counters - Newly, in the Simple version, you can specify the values for any number of counters that are displayed in actual values. - Added new language: Swedish. Release 1.0.5.68 (2022-08-26): - Fix for setpoints to insert into status. - Added a button to reset the SRM module to default values. - Fix display of battery change buttons. - Optimization of Modbus map and call windows. - Fixed status display for analogues in actual values. - Correction of parameter exports to PDF. - Fix decimal separator for Danish. Release 1.0.5.67 (2022-07-15): Release 1.0.5.66 (2022-07-08): - Added new properties for the billing archive - Time setting optimization - New translations of texts. - Optimization of the exchange of counters in the standard version. - Added buttons for replacing the device's battery and the modem's battery. Release 1.0.5.65 (2022-05-30): - Fix: counter display in standard version - Standard version: add button for maps (call, SMS, CTR) - Parameter window: added button to check I / O occupancy - New language: Danish - Fixed density input Release 1.0.5.64 (2022-04-22): - Fix: resetting the summary status of diagnostics - Fix: showing data of status when opened from DT file. - Fix: editing cells in the switching window. - Fix: showing of communication ports. - Fix: Dial number (modem) in the standard version of the software. - Fix in modbus map window and in the template of modbus map. Release 1.0.5.63 (2022-03-09): - Edit map of quick buttons for segment display - Modem addition and deletion fixes. - Parameter check adjustment. - Fixed offering free modems on communication ports. - Allow other items in the Text map. SMS and quick buttons. Release 1.0.5.62 (2022-03-09): - Calorific value and density are newly rounded to 4 decimal places. - Modification of the enumeration for switching off the IR head in the system. - Adjustment for keyboard FW recording. Release 1.0.5.61 (2022-01-28): - The FW can now be loaded into the keyboard - DT file creation optimization - Added new features to Daesung client - Correction of period settings in the EXT module - Fixed a bug when reading actual values for a long time - Correction of binding settings in the spare base volume Release 1.0.5.60 (2021-12-01): - Newly, some derived measurands display decimals and units. - Fixed a bug when changing the number of places at Vb and rewriting into derived measurands. - Fix: units / des. places at Q and Vm and derived measurands. - Fix: counter value setting in Simple version - DSFG protocol: fixes and optimizations. Release 1.0.5.59 (2021-11-11): - New DSFG client added - DSFG communication protocol added. - Added control message when encryption / logging is enabled on the communication port. Release 1.0.5.58 (2021-10-08): - Correction of billing archive settings (system parameters). - Fix: the button for changing the counter is displayed even if the counter is in the HW device. - The program now has a modbus map check, Map check button. There is a filter for sorting. - Can be added / deleted / edited: Daesung client, FTP client, HTTP client, Time synchronization. It is in the calculated measurands. - The station name is added to the file name when exporting archives. Release 1.0.5.57 (2021-09-01): - Parameters: The device serial number (CTRL + C) can now be copied using the icon. Release 1.0.5.56 (2021-08-18): - Added functionality that opens "module parameters" of the device from the * .DT_all file. Release 1.0.5.55 (2021-07-20): - New: Logging of communication according to the serial number of the device. Each device has its own file in the format rs232_VYR_C.log Release 1.0.5.54 (2021-06-17): - Fixed: The listening port on the modem is always displayed. Release 1.0.5.53 (2021-06-10): Release 1.0.5.52 (2021-04-19): - Modbus map - fix function after clicking OK button, if modem properties were added. - Fixed: Creating an empty tariff window. - For outputs (analog, binary, impulses), it is displayed whether the output is enabled / disabled (green / red). After moving to the image of the question mark, it is displayed that it is being edited in DataStructure / Output signals. Release 1.0.5.51 (2021-03-16): - Added information about whether there is a barometer in the device, it is displayed only if we are standing on the value bar. pressure in the HW device. - If the sensor is adjusted, it is reported that the command was executed and the window is read again, where we see the new values after the adjustment. - Fixed: unit conversion for reference values + the temperature limit is recalculated according to the temperature unit. - The DT_ALL file adds the date and time after the station name, so it will not be overwritten the next time it is read. It remained the same for ordinary DT files. - Fixed: L,H - gas.