Basic features

    • Designed to be used for installation in hazardous area – Zones 0, 1 and 2
    • Battery lifetime more than 5 years
    • Fully configurable device (Telves service tool)
    • Graphical LCD backlit display 128 x 64 pixels
    • Possibility to connect up to six sessors (pressure, temperature)
    • Possibility to connect second Data Logger as subsystem
    • Typical error under reference conditions < 0.15 % from measured value
    • Certificate FTZU 09 ATEX 0290X
    • Protection class IP 66
    • Working temperature -25°C to +70°C

Communication

    • Serial interface RS-232 / RS-485
    • Optical interface IEC 62056-21
    • GSM/GPRS modem

    Inputs / Outputs

    • 4 + 2 digital inputs
    • 4 digital outputs
    • 2 analog inputs (maxiDATCOM EXT1 or maxiDATCOM GSM EXT1)
    • Up to 4 analog outputs realized via CL1 module ( 4-20mA)

maxiELCOR variants

  •                         maxiDATCOM GSM   Single channel device equipped with GSM/GPRS modem
    maxiDATCOM GSM EXT1   Single or dual channel device equipped with GSM/GPRS modem with additional inputs and outputs
    maxiDATCOM EXT1   Single or dual channel device equipped with additional inputs and outputs (without modem)

Optional accessories

    • Thermowell, montážní sada, trojcestný ventil (typ DN 3 PN 100)
    • Digitální snímače tlaku EDT 23 nebo teploty EDT 34
    • Optické hlavice HIE-03 (RS232) nebo HIE-04 (USB)
    • Modul proudového výstupu CL1 (4 – 20)mA
    • Jiskrově bezpečný napájecí zdroj JBZ-04
    • Komunikační moduly DATCOM K3/K4
    • Rozšiřující komunikační modul RS485 (připojení digitálního převodníku nebo dalšího přepočítávače)
    • Servisní a nastavovací SW Telves