Device Archive

Gas-volume conversion device ELCOR-2

Gas-volume conversion device ELCOR-2

Gas-Volume Conversion Device ELCOR-2 is a measuring instrument intended for gas volume conversion under operating conditions to volume under standard conditions.
The information about flow-through gas volume is scanned via impulse gas meter outputs, the temperature and gas pressure are measured by digital transducers. Gas compresibility degree is calculated by a device according to the routine methods or any constant value is used.

DATCOM-AMR1

DATCOM-AMR1

GSM/GPRS communicator DATCOM-AMR1 is designed for remote data transfer from electronic gas volume correctors miniELCOR, ELCOR-2 and their alternatives. Simple design ensures reliable and safety functioning.

DATCOM-AMR2

DATCOM-AMR2

Battery powered GSM/GPRS communicator DATCOM-AMR2 offers advanced telemetric functions such as collecting data from connected correctors, digital inputs, internal states and communicates with superior systems. Device has been designed for installation in hazardous areas.

!! Device production was terminated !!

DATCOM-AMR3/S

DATCOM-AMR3/S

GSM/GPRS communicator DATCOM-AMR3/S belongs to category of Automatic Meter Reading devices. DATCOM-AMR3/S device is very good solution for distribution places without mains power supply. It meets the customer's needs for frequent data reading from remote meters. Device is constructed to be placed in hazardous area and supplied from accumulator charged by solar panel.

DATCOM-AMR3/E

DATCOM-AMR3/E

GSM/GPRS communicator DATCOM-AMR3/E belongs to category of Automatic Meter Reading devices. DATCOM-AMR3/E meets the customer's needs for frequent data reading from the meters and proceeding them to the superior system using GSM/GPRS cellular network. Device is constructed to be placed in non-hazardous area and it is powered from 230V AC mains with backup.

miniDATCOM

miniDATCOM

Battery powered Data Logger with option of external power supply. miniDATCOM is excelent price/performance ratio solution for metering and data collection systems. To provide telemetry data collection miniDATCOM can be installed with GSM/GPRS communicator AMR.

midiDATCOM

midiDATCOM

Battery powered Data Logger with integrated GSM/GPRS modem, optionally supplied from external power supply. This compact midiDATCOM design offers ideal solution for telemetry data collection.

maxiDATCOM

maxiDATCOM

Battery powered Data Logger with integrated GSM/GPRS modem, optionally supplied from external power supply. Single or dual channel maxiDATCOM with large variability of expansion boards offers complete solution for telemetric data collection.

DATCOM-2

DATCOM-2

Electronic datalogger DATCOM-2 is device which is determined for temperature and pressure measuring. DATCOM-2 may have 4 as the case may be 6 temperature and pressure sensors.

nanoELCOR

nanoELCOR

Battery powered nanoELCOR with integrated GSM/GPRS modem can be installed as stand alone volume corrector. This device is however designed to be mounted on the diaphragm gas meters. Such solution brings a challenging opportunity to implement high performance and excelent price for smart metering.

Gas-volume conversion device microELCOR-2

Gas-volume conversion device microELCOR-2

MicroELCOR-2 is battery gas volume conversion device with option of external power supply.MicroELCOR-2 performs conversion of gas volume at measurement conditions to volume at base conditions based on measured operational pressure and temperature.

For calculation of compressibility can be used fixed compressibility, methods AGA NX19, AGA NX19 mod, SGERG 88, AGA 8-G1 or AGA 8-G2.

Impulse sensor IS-09

Impulse sensor IS-09

Impulse sensor IS-09 complements gas meter RPT 3 with low frequency non-potential impulse output used for gas-volume conversion devices. The principle of impulse sensor is fastening and unfastening reeds relay in magnetic field with cyclically variable intensity.

miniELCOR

miniELCOR

Battery powered EVC with option of external power supply. miniELCOR is excelent price/performance ratio solution for metering and data collection. To provide telemetry data collection miniELCOR can be installed with GSM/GPRS communicator AMR.

midiELCOR

midiELCOR

Battery powered EVC with integrated GSM/GPRS modem, optionally supplied from external power supply. This compact midiELCOR design offers ideal solution for telemetry data collection and billing.

maxiELCOR

maxiELCOR

Battery powered EVC with integrated GSM/GPRS modem, optionally supplied from external power supply. Single or dual channel maxiELCOR with large variability of expansion boards offers complete solution for telemetry data collection and billing.

DATCOM

DATCOM

Electronic Datalogger DATCOM is a battery powered device intended for measurement and recording the time behaviour of physical quantities. This device is fed from an internal battery with long service life and there is also enabled the connection of external source.

Note:Production of the device was ended.

Limit switch KS 06

Limit switch KS 06

Limit switch KS 06 is designed to be used for slam-shut safety valves to signal interruption of operating medium supply caused by closing of a  slam-shut safety valve.

Gas-volume conversion device ELCOR-94

Gas-volume conversion device ELCOR-94

ELCOR-94 is battery powered electronic corrector, converting the gas volume to be flown through gas meter to referential conditions of pressure and temperature. For natural gas calculates the gas compressibility degree according to ČSN 38 5510. Measured values of temperature, pressure and operating volume and calculated values of standardised volume are stored into device memory.

Power supply JBZ-01

Power supply JBZ-01

Intrinsically safe power supply JBZ-01 designed for assembly on DIN bar 35 mm. Power supply serves as external power supply for electronic volume corrector ELCOR-94.

Infrared communication head HIE-01

Infrared communication head HIE-01

Infrared communication head HIE-01 is intended for data transmission between personal computer and gas-volume conversion device ELCOR-94, µ-ELCOR or datalogger DATCOM. This is produced in accordance with norm ČSN EN 61107.

Head is connected to serial port RS232C of computer, from which is simultaneously fed. It is produced for communication speed up to 9600 Bd.

Current loop CL-1 Module

Current loop CL-1 Module

CL-1 Current Loop module serves as a converter of digital signal to current output signal 4-20mA. Module can be connected to ELCOR-2 or xELCOR/xDATCOM series

Communication module DATCOM-S1,S2

Communication module DATCOM-S1,S2

The module DATCOM-S1 ensures communication of a personal computer (PC type) or a modem with data recorders DATCOM and gas volume converters of the types ELCOR-94 and µ-ELCOR.

The module DATCOM-S2 is a simplified version of the module DATCOM-S1. It ensures communication of a personal computer (PC type) or a modem with the data recorders DATCOM and gas converters of the type ...

Power Supply JBZ-03

Power Supply JBZ-03

JBZ-03 intrinsically safe power supply serves as external power supply for gas volume corrector miniELCOR and GPRS communicator AMR1.

Power Supply JBZ-04

Power Supply JBZ-04

JBZ-04 intrinsically safe power supply serves as external power supply for gas volume correctors with integrated GSM/GPRS modem - midiELCOR or maxiELCOR.

System DATCOM-RTU

System DATCOM-RTU

System DATCOM-RTU is intended for monitoring technological processes, transferring recorded data to superior system, watching limiting values, and transferring alarm reports by calling to superior system and regulating slow processes (max.0,5Hz). This system is also constructed for measuring signals coming from hazardous area, while some of its modules can be directly placed in this area.

DATCOM-RTU - module SIO

DATCOM-RTU - module SIO

Communication line module SIO

Module serves for connecting devices with serial communication into system. In modules can be programmed conversion from strange protocol to Modbus used by internal busbar. Available is cache memory for buffering.

HIE-03 infrared head

HIE-03 infrared head

RS232 infrared optical head HIE-03 can be used for communication with Elgas s.r.o. devices. HIE-03 has been designed according to EN 62056-21 standard (former IEC-1107 standard) and can communicate with baud rate up to 38400 Bd.

DATCOM-RTU - module COM

DATCOM-RTU - module COM

Module of communication exciter COM

Module is intended for transformation communication signals of system busbar from level TTL to RS-485 and vice versa. Controlling transformation direction is automatic; module recognizes itself, if it should transfer TTL to RS-485 or vice versa.

Gas-volume conversion device µ-ELCOR

Gas-volume conversion device µ-ELCOR

µ-ELCOR is a battery powered electronic conversion device. Gas volume measured by gas meter at the operating conditions is converted in the device to the volume of gas under referential conditions of pressure and temperature.

Measured values of operating volume and calculated values of normed volume are stored into memory of device.

Intrinsically safe circuit JBO-01

Intrinsically safe circuit JBO-01

Intrinsically safe circuit JBO-01 is designed for transformation of input voltage to intrinsically safe binary output. Primarily is intended for reading presence of network voltage for adjustment of other voltage signals for the purpose of connection to binary and impulse inputs of electronic datalogger DATCOM.

Telemetric box TES-01

Telemetric box TES-01

The telemetric box TES-01 ensures remote communication with the electronic battery powered gas volume corrector µ-ELCOR. The box shall be located outside hazardous (explosive) area. The communication is via dialled connection by means of a GSM modem, which constitutes a part of the box TES-01.

DATCOM-RTU - module DIO-8

DATCOM-RTU - module DIO-8

Digital inputs and outputs module DIO-8 (DIO-8/IS)

Module DIO-8 is intended for evaluation of binary or impulse input signals and generation binary or impulse output signals. During reading impulse signals, module counts number of pulses and evaluates its growth for time unit (flow, frequency). NF impulse inputs and outputs and states of counters are backed-up with lithium battery for case of disconnection...

DATCOM-RTU - module AO-2

DATCOM-RTU - module AO-2

Analogue outputs module AO-2

Module is mounted by two current outputs 4-20 mA. Both outputs are galvanically separated from system busbar and from each other. For feeding of outputs is in module mounted converter, which is also galvanically separated from outputs and from system busbar.

Backup module DATCOM-Z1

Backup module DATCOM-Z1

Backup module DATCOM-Z1, this module provides the power supply of communication circuits of DATCOM-K1 module in case of the mains power failure, in order to communicate in such situation with an end device, such as for example datalogger DATCOM or gas-volume corrector ELCOR-94.

DATCOM-RTU - module AI-7

DATCOM-RTU - module AI-7

Analogue inputs module AI-7 (AI-7/A) Two variants.

In standard variant AI-7 module serves for measuring unified analogue signals (voltage, current and resistance), primarily from transducers of other producers.

In variant AI-7/A is module intended for measuring signals from...

DATCOM-RTU - module CPU

DATCOM-RTU - module CPU

Central unit CPU

Module CPU is main element of the whole system, it conducts collection of measured data from other modules and digital transducers and its storage. It communicates with superior system via serial interface RS-232 (9 pole connector on the front panel) or RS-485 (terminal on front panel of module), during communication via module DISP makes use of optical...

DATCOM-RTU - module UPS

DATCOM-RTU - module UPS

Back-up module UPS

Module UPS serves for backing-up supply voltage for system modules and for communication devices (modem…). For feeding of other devices (for instance external sensors) is back-up supply voltage also brought to module terminal.

DATCOM-RTU - module ISS

DATCOM-RTU - module ISS

Intrinsically safe source module ISS

Module ISS is in system DATCOM-RTU mounted only on the basis of securing inexplosiveness requirement, concretely type of protection “Intrinsic safety” (EEx ia).

DATCOM-K1

DATCOM-K1

Intrinsically safe communication interface DATCOM-K1 can be connected to ELCOR-2, microELCOR-2 or xELCOR/xDATCOM series. Provides RS232/RS485, baud rate and protocol coversion.


Contacts

ELGAS, s.r.o.

Semtínská 211

Ohrazenice
533 53 Pardubice

E-mail: obchod@elgas.cz
Tel.: +420 466 414 500

See more our contacts >>


© 2020 Elgas s. r. o.

Private policy | Sitemap

Created by eBRÁNA s.r.o. | Powered by WebArchitect | SEO a internetový marketing

to top ↑